
Encoder User Manual
Manual-H264_ENC-Rev1207A
Copyright © KBC Networks 2012 Page 9 of 49
www.kbcnetworks.com
2.2.6.3 RS-232
(Use RS-232 dip switch selection)
From encoder: TX+ to camera: Transmit
From encoder: RX+ to camera: Receive
From encoder: GND to camera: Ground
2.2.6.4 Known Incompatible Protocols
The following data protocols are not supported by the KBC encoder/decoder:
• Sensornet
• Biphase & Bilinx, other Bosch proprietary protocols
• Kalatel protocols using RS-422. The system is compatible in RS-485 at 9600
Baud Rate
• Coaxitron or other “up the coax” PTZ control systems
2.2.7 Alarm Input / Output Parameters
2.2.7.1 Voltage Specification
Contact Closure Specification
DI Connection Design TTL-compatible logic levels
Voltage
Trigger
(low)
Logic level 0: 0V ~ 0.4V
Normal
(high)
Logic level 1: 3.1V ~ 30V
Current 10mA ~ 100mA
DO Connection Design TTL-compatible logic levels
Voltage
Trigger
(high)
Logic level 0: 2.4V ~ 5V
Normal
(low)
Logic level 1: 0.1V ~ 0.6V
Current 50mA
Comentarios a estos manuales